Electric Power Monitors and Transducers
Heavy current engineering

Internationally accepted Swiss precision for optimum energy management.

The deregulation of energy markets and globally increasing environmental awareness define a high degree of responsibility for companies to treat power as a precious resource. Camille Bauer provides a wide spectrum of innovative and highly efficient power measurement and analysis products.

Our extensive product line is manufactured in accordance with individual customer specifications and their functionality is adapted to your requirements in order to guarantee optimum results. Custom-made measuring performance has always been part of our service.

Camille Bauer Industrial Catalog pdf
  • Sineax Power Products
  • Power Meters and Monitors
  • Power Analysis
  • Power Transducers
  • Sineax Software
Camille Bauer Industrial Catalog
How to Order
  1. Select your model
  2. See data sheet for ordering info and options
  3. Call 800-942-0315 for ordering assistance and a quotation
  4. 3 to 4 week typical lead time (USA customers)
  5. To place your order
Multi-Function Power Meters
DM5S, DM5F Universal Power Transducer with MODBUS Interface and/or Analog Outputs
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz

Output: Up to 4 analog outputs and/or MODBUS interface
  • DM5F: Fast response version
  • System state monitoring: class 0.2
  • Energy metering class 0.5S
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • USB PC programming interface
  • Configure using CB Manager software
  • 24-230 VDC or 100-230 VAC powered

DM5 Data Sheet
DM5 Instructions

MODBUS Basics
MODBUS Instructions
CB Manager Software

new DM5
profibus logo CE logo UL
Sineax CAM Multifunction Energy Transducer
Input: 0-1A, 0-5 A from CT or Two 4-20 mA, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz, Digital I/O

Output/Communications: RS-485 MODBUS, Relay, Up to 4 analog, Digital I/O, USB 2.0 programming interface
  • True RMS
  • Simultaneous measurement of all 3 phases
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
  • 85-265 VAC/ 110-265 VDC powered
  • Optional 17-90 VDC powered
CAM Brochure
CAM with Rogowski Sensors
Rogowski Sensors Brochure
CAM Data Sheet
CAM Instructions
CAM Instruction Supplement for Graphic Display
CAM Safety Instructions

CAM Installation of IEC 61850 option
CAM Instructions for IEC 61850 option
CAM IEC 61850 Certificate

CB Manager Software
CB Data Analylysis Software
CAM ICD Files
MODBUS Basics
MODBUS Instructions
MODBUS/TCP Instructions
CAM
CAM with display
Modbus

IEC 61850

  CE logo
Sineax A200 Multifunction Display for DME Power Transducers
Input: Serial data from DME4 series

Output: 3 digital displays
  • 1/4 DIN (96 x 96 mm) display for DME4 transducers
  • Triple LED display 14 mm digit height
  • Selectable display parameters
  • 20-265 VAC/VDC powered

Data Sheet
Instructions
DIN Rail Adapter
CE logo A200 Din bracket
Power Transducers
Sineax P 530 Active Power & Q 531 Reactive Power Transducers
Input: 0-0.8 A to 0-1.2 A or, 0-4 A to 0-6 A, 100-690 V, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • 3-Phase with Balanced or Unbalanced Load
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions, Single Phase Models
Instructions, 3-Phase Models
CSA Certificate
GL Certificate for Shipboard Use, 3-Phase Version
P 530

CE logo  CSA logo  Germanischer Lloyd
Current Transducers
Sineax I 538 AC Current Transducer
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
I 538

CE logo  CSA logo  Germanischer Lloyd
Sineax I 542 AC Current Transmitter
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Powered from Measuring Source
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
I 542

CE logo  CSA logo  Germanischer Lloyd
Sineax I 552 True RMS AC Current Transducer
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT , 50/60 or 400 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
I 552

CE logo  CSA logo  Germanischer Lloyd
Voltage Transducers
Sineax U 539 AC Voltage Transducer
Input: 0-50 V to 0-600 V, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
U 539

CE logo  CSA logo  Germanischer Lloyd
Sineax U 543 AC Voltage Transducer
Input: 0-20 V to 0-600 V, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Powered from Measuring Source
Data Sheet
Instructions
CE Declaration
CSA Certificate
GL Certificate for Shipboard Use
U 543

CE logo  CSA logo  Germanischer Lloyd
Sineax U 553 True RMS AC Voltage Transducer
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V]
  • Sine, Rectangular or Distorted Wave Forms
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
U 553

CE logo  CSA logo  Germanischer Lloyd
Sineax U 554 True RMS AC Voltage Transducer
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Special Version to Allow Zero Offset
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
U 554

CE logo



Frequency Transducers
Sineax F 534 Frequency Transducer
Input: 10 V to 690 V, 10 to 1500 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
F 534

CE logo  CSA logo  Germanischer Lloyd
Sineax F 535 Frequency Difference Transducer
Input: 10 V to 690 V, 10 to 1500 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
  • Measure Δf Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
F 535

CE logo  CSA logo  Germanischer Lloyd
Phase Angle (Power Factor) Transducers
Sineax G 536 Phase Angle Transducer
Input: 1 or 5 A from CT, 10 V to 690 V, 16 to 400 Hz, 0.5 cap. 1.ind. 0.5 cos Φ

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • Measure Single or 3-Phase Balanced
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
g 536

CE logo  CSA logo  Germanischer Lloyd
Sineax G 537 Phase Angle Difference Transducer
Input: 10 V to 690 V, 50 or 60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • Measure ΔΦ Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Instructions
CSA Certificate
GL Certificate for Shipboard Use
G 537

CE logo  CSA logo  Germanischer Lloyd
Power & Current Transducers
Sineax M 561 Power & Current Transducer
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz

One Analog Output: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
  • 1 analog output
  • Measures any One: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
M 561/562/563 Series Data Sheet
M 561/562/563 Series Instructions
M 561 CSA Certificate
Software for M561/562/563 series
M 561

CE logo  CSA logo
Sineax M 562 Power & Current Transducer
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz

Two Analog Outputs: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
  • 2 analog outputs
  • Measures any two: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
M 561/562/563 Series Data Sheet
M 561/562/563 Series Instructions
M 562 CSA Certificate
Software for M561/562/563 series
M562

CE logo  CSA logo
Sineax M 563 Power & Current Transducer
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz

Three Analog Outputs: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
  • 3 analog outputs
  • Measures any Three: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
M 561/562/563 Series Data Sheet
M 561/562/563 Series Instructions
M 563 CSA Certificate
Software for M561/562/563 series
M 563

CE logo  CSA logo