• Overview of all Sineax models
  • Passive Isolators
  • Signal conditioners
  • Signal isolators
  • Signal transmitter
  • Loop power supplies
  • Sineax software and cable overview
Camille Bauer Industrial Catalog pdf
Camille Bauer Industrial Catalog
Passive Isolators
Sineax TI 816 Signal Isolator 500 V
Input: 0-20 mA, 4-20 mA

Output: 0-20 mA, 4-20 mA, 0-10 V to 2-10 V
  • Loop-Powered Passive Device
  • Order with V or mA Output
  • 600 Ω Maximum Burden (Current)
  • 500 Ω Maximum Burden (Voltage)
  • Only 0.5" (12.5 mm) Wide
  • Low Cost
CE logo Data Sheet
Instructions
TI 816
Sineax DCM 817 Signal Isolator 500 V
Input: 0-20 mA, 4-20 mA

Output: 0-20 mA, 4-20 mA
  • Circuit Board Mounted
  • Straight Pins or 90° Pins
  • Loop-Powered Passive Device
  • 600 Ω Maximum Burden
  • Compact and Cost Effective OEM Solution
CE logo Data Sheet
DCM 817st DCM817
Sineax SI 815-5 and SI 815-1 Signal Isolators Up to 2300 V Isolation
Input: One or Two 4-20 mA

Output: One or Two 4-20 mA hart logo
  • Single Channel (SI 815-5) and Two Channel (SI 815-1) Versions
  • Output Loop Powered (12-30 V)
  • Transfers Power to Input Loop
  • Optional HART Protocol
CE logo Data Sheet Both Versions
Instructions Single Channel Versions
Instructions Two Channel Versions
SI 815-1 two channel
Sineax TI 807-5, TI 807-1 Signal Isolators up to 4000 V Isolation
Input: One, Two, or Three 0-20 mA, 4-20 mA, 0-10 V

Output: One, Two, or Three 0-20 mA, 4-20 mA, 0-10 V
  • Single Channel (TI 807-5) and Two/Three Channel (TI 807-1) Versions
  • Loop-Powered Passive Device
  • 1000 Ω Maximum Burden
  • Factory Ranged
CE logo Data Sheet All Versions
Instructions Single Channel Versions
Instructions Two or Three Channel Versions
sineax ti807


Signal Conditioners, Isolators and Transmitters
Sineax TV 819 Low Cost Process Transmitter
Input: 0-60 mV to 0-1000V, 0-20 mA to ±40 mA

Output: 0-20 mA to ±20 mA, 0-10 V to ±10 V
  • Fully Isolated
  • Removable Plugs
  • Unipolar or Bipolar Input and Output
  • Factory Configured
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
sineax tv819Sineax TV 809 Programmable Process Transmitter
Input: 0-30 mV to 0-1000V, 0-20 µA to 0-100 mA

Output: 0-20 mA to ±20 mA, 20-4 mA, 0-10 V to ±10 V, 10-0 V
  • Fully Isolated
  • Removable Plugs
  • Unipolar or Bipolar Input and Output
  • Reverse Output Available
  • Custom 57 Point Input Linearization
  • Optional Programmable Relay Alarm
  • PC Programmable
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
TV800Plus Software
TV 809
Sineax V 604s Programmable Universal Transmitter
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo Brochure
Data Sheet
Instructions
Safety Instructions
CB Manager Software
V604s
Sineax VB 604s Programmable Universal Transmitter w. Remote I/O
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Control of Relay and Outputs via Modbus
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo
Data Sheet
Instructions
Safety Instructions
CB Manager Software USB Driver
V604s
Sineax VC 604s Programmable Universal Transmitter w.
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ
One Output: 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Alarms: Two SPDT Relays
Communications: Control of Relay and Outputs via Modbus
  • Input redundancy and drift monitoring
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo
Data Sheet
Instructions
Safety Instructions
CB Manager Software USB Driver
V604s
Sineax VQ 604s Fast Response Programmable Universal Transmitter w. Remote I/O
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ
Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Control of Relay and Outputs via Modbus
  • Up to 10 millisecond response time
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo
Data Sheet
Instructions
Safety Instructions
CB Manager Software USB Driver



V604s



Temperature & Universal Transmitters
Sineax V 611 Ultra-Slim Temperature Transmitter
Input: Thermocouple or RTD
Output: 4-20 mA or 20-4 mA
  • 9 mm (0.35") wide
  • PC Programmable
  • Reverse Output Capable (20-4 mA)
  • 100 Ohm RTD, 2, 3, or 4-wire
  • T/C J, K, T, E, R, S,N, B, L, U, W5, W3
  • Input Linearization
  • Non-Isolated
  • Internal or External CJC
  • Supply Voltage: 12-30 VDC from Output Loop
CE logo Data Sheet
Instructions
V600Plus Software
Sineax V611
Sineax V 608 Temperature Transmitter
Input: Thermocouple, RTD

Output: 4-20 mA
  • PC Programmable
  • Programmable Sensor Fault Response
  • Non-Isolated
  • 12-30 VDC Loop-Powered
CE logo Data Sheet
Instructions
V600Plus Software
V608
Sineax V 624 Programmable Temperature Transmitter
Input: Thermocouple, RTD, Thermistor, Custom

Output: 0-2 mA to 0-20 mA, 20-0 mA, 0-1 V to 0-10 V, 10-0 V
  • PC Programmable
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Sensor Fault Response
  • Removable Plugs
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
V624 external CJC
V624 internal CJC
V600Plus Software
V624
Sineax V 604s Programmable Universal Transmitter
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo Brochure
Data Sheet
Instructions
Safety Instructions
CB Manager Software
V604s
Sineax VB 604s Programmable Universal Transmitter w. Remote I/O
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Control of Relay and Outputs via Modbus
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo
Data Sheet
Instructions
Safety Instructions
CB Manager Software USB Driver
V604s
Sineax VC 604s Programmable Universal Transmitter w.
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ
One Output: 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Alarms: Two SPDT Relays
Communications: Control of Relay and Outputs via Modbus
  • Input redundancy and drift monitoring
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo
Data Sheet
Instructions
Safety Instructions
CB Manager Software USB Driver
V604s
Sineax VQ 604s Fast Response Programmable Universal Transmitter w. Remote I/O
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ
Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Control of Relay and Outputs via Modbus
  • Up to 10 millisecond response time
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo
Data Sheet
Instructions
Safety Instructions
CB Manager Software USB Driver



V604s